[Oral Presentation]A NOVEL FAULT DETECTION OF IGBT OPEN –CIRCUIT FAILURE IN FIVE- PHASE OPEN-END WINDING PMSM DRIVE SYSTEM

A NOVEL FAULT DETECTION OF IGBT OPEN –CIRCUIT FAILURE IN FIVE- PHASE OPEN-END WINDING PMSM DRIVE SYSTEM
ID:133 Submission ID:1303 View Protection:ATTENDEE Updated Time:2020-11-02 16:38:05 Hits:261 Oral Presentation

Start Time:2020-11-03 11:30 (Asia/Shanghai)

Duration:15min

Session:[C] Electric Machine Design and Control » [C1] Session 12 and Session 17

Video No Permission Presentation File

Tips: The file permissions under this presentation are only for participants. You have not logged in yet and cannot view it temporarily.

Abstract
In order to improve the reliability of motor drive systems, the device faults in the voltage-source inverters should be detected immediately. Aiming at this problem, this paper presents a novel open-circuit fault detection method for five-phase open-end winding permanent magnet synchronous motor (PMSM) drive system. In this paper, the characteristics of zero sequence current in faulty condition are analyzed. Compared with neutral connected PMSM, the zero sequence current will change differently according to the different faulty conditions. Thus the zero sequence current is used to detect the fault. By comparing zero sequence current with phase currents, the faulty phase and condition can be detected. The confirmation time is adopted to improve the reliability. The effectiveness of the proposed method is verified by simulation.
 
Keywords
five-phase, open-end, fault detection, zero sequence current
Speaker
Chunyang Jiang
Harbin Institute of Technology

Submission Author
Chunyang Jiang Harbin Institute of Technology
Hongchen Liu Harbin Institute of Technology
Desong Chen Harbin Institute of Technology